- Venting and Exhaust Fans
Oil-Fired Generator Chimney Installation
A dedicated stainless steel chimney for an oil-fired generator, routed up the exterior wall and terminated above the roofline.
When a boiler stack, kitchen exhaust, or building flue will not draft, we find the true cause, engineer the correction, and verify the result under normal operating conditions. One team from the first pressure test to the certified, code documented fix.
OVERVIEW
Commercial draft problems rarely resolve on their own. Stack effect in tall buildings, competing exhaust systems, undersized or oversized flues, and aging boiler stacks pull venting out of balance, and the result is backventing into occupied spaces, appliance shutdowns, and failed inspections. As a commercial chimney contractor, we correct the underlying cause rather than treating the symptom, using pressure testing under normal operating conditions to confirm exactly where and why the system fails.
Draft correction is a diagnostic discipline before it is a repair. We measure how the stack, flue, and connected appliances behave together, then engineer a scope that brings the venting back into balance, whether that calls for resizing, resealing, rerouting, extending the stack, or adding mechanical draft with a chimney fan. Property managers, building owners, and general contractors get one accountable team from the diagnosis through the documented result.
WHEN YOU NEED IT
Combustion byproducts pushing back into tenant units, corridors, or common areas point to a draft that has reversed and needs correction before it becomes a carbon monoxide and liability issue.
A commercial boiler that struggles to fire, cycles short, or shuts down on safety usually signals a venting fault in the stack or flue that draft correction resolves.
When a kitchen hood or exhaust stack fails to move air, grease, heat, and odor stay in the space, and mechanical interference from surrounding systems is often the cause.
New or existing high rise neighbors change wind pressure at the roofline and force air back down the flue, a pattern common across dense NYC blocks.
Visible soot, discoloration, or condensate near a boiler or appliance indicates incomplete venting and combustion gases that are not clearing the system.
A venting failure noted by an inspector or engineer requires documented correction, and we deliver the engineered fix along with the paperwork that closes it out.
OUR PROCESS
We inspect the stack, flue, appliances, and surrounding exhaust systems, then run a stack effect analysis to identify the true source of the draft problem.
We pressure test the system under normal operating conditions to measure performance, locate leakage, and confirm the corrective approach with data rather than assumption.
Within 48 hours we deliver a scoped proposal with engineered drawings where design and permit filing are required, plus lead times and pricing.
We install the corrective components, whether resizing, resealing, rerouting, extending the stack, or adding a chimney fan, with a protocol built for occupied buildings and minimal downtime.
We retest until the system passes, then issue a certificate of functionality with photographic documentation for your records.
COMPLIANCE
CERTIFICATION
Written certification that the corrected system meets applicable NYC Mechanical Code chimney and vent provisions.
FILING
Engineered drawings and permitting support for corrections that require filing and sign off.
EVIDENCE
A detailed draft testing report with photographic documentation and a certificate of functionality for owner and insurer records.
WHY US
Pressure testing under normal operating conditions and stack effect analysis identify the real cause instead of the obvious symptom.
We phase and schedule corrections around tenants and continuous operations to keep boilers and kitchens running with minimal downtime.
We correct venting on commercial boiler stacks and flues where short cycling and safety shutdowns trace back to a draft fault.
One team owns the diagnosis, engineering, correction, installation, and warranty registration from quote through sign off.
Venting failures and boiler shutdowns get a fast response so heat and safety are restored quickly.
Every correction closes with code paperwork, photographic reporting, and a certificate of functionality.
WHO WE SERVE
We correct draft problems for property managers, building owners, general contractors, mechanical contractors, and facility engineers, and we subcontract cleanly for GCs and mechanical teams that need a specialist for the venting scope.
Serving Brooklyn, Manhattan, the Bronx, Queens, Staten Island, and Long Island.
OUR WORK
A dedicated stainless steel chimney for an oil-fired generator, routed up the exterior wall and terminated above the roofline.
A severely deteriorated rooftop chimney stack was dismantled to a sound base and rebuilt in new red brick, with a new crown and a stainless steel cap.
A failing chimney with crumbling mortar, damaged brick and a broken crown, fully dismantled and rebuilt with a new concrete crown, cap and weather-sealed base.
REVIEWS
FAQ
The common causes are stack effect in tall buildings, competing exhaust systems such as HVAC, kitchen hoods, and dryer vents, undersized or oversized flues, and aging boiler stacks. We test to confirm which factors are at work before proposing a correction.
We run a stack effect analysis and pressure test the system under normal operating conditions, which measures actual performance and locates leakage rather than relying on assumptions.
Yes. We phase and schedule the correction around tenants and continuous operation so boilers, kitchens, and common areas stay usable with minimal downtime.
Yes. For corrections that require design and filing we work with a registered design professional, and every project closes with written certification, a report, and photographic documentation.
When mechanical draft is the correct engineered solution we handle chimney fan installation and repair as part of the correction.
Yes. We provide 24/7 emergency service for boiler shutdowns and venting failures to restore heat and safety quickly.
Yes. We work as the venting specialist on projects led by GCs and mechanical contractors, delivering diagnosis, drawings, correction, and documentation to spec.
Get a diagnosis, an engineered plan, and a corrected venting system from one accountable team. Proposals in 48 hours, emergency service around the clock.
MANUFACTURING
Most contractors diagnose a draft problem and then wait on a distributor for the parts that solve it. Because we manufacture our own UL Listed stainless steel components, we can produce the exact liner, extension, reroute, damper, or custom cap a correction needs, sized to the stack and the building. That keeps lead times short and puts the design and the hardware under one accountable team.